Model NO.
CPN49-600
Application Fields
General Industry Field
Certification
ISO
Condition
New
Noise Level
Low
Parts
Tanks, Valves, etc
Purpose
Gas Manufacturing
Usage
Industry, Nitrogen
Machine Size
It Depends The Client Requirement.
Trademark
HYT
Transport Package
Export Package
Specification
The actual dimension
Origin
China
Product Description
How PSA Nitrogen Generator works?
PSA, short for Pressure Swing Adsorption, is a kind of the advanced technology for air separation, and it plays an irreplaceable role in nowadays on-site gas supplying.
PSA nitrogen generation usually adopts two adsorption towers, which are filled with the Carbon Molecular Sieve (CMS). CMS has many tiny holes, under certain pressure, the tiny holes have different adsorption capacity to nitrogen and oxygen. When one tower adsorbs oxygen and produces nitrogen, the other desorbs oxygen and makes regeneration. This alternate process constantly produces nitrogen.
PN Series: Technical Specifications
PSA, short for Pressure Swing Adsorption, is a kind of the advanced technology for air separation, and it plays an irreplaceable role in nowadays on-site gas supplying.
PSA nitrogen generation usually adopts two adsorption towers, which are filled with the Carbon Molecular Sieve (CMS). CMS has many tiny holes, under certain pressure, the tiny holes have different adsorption capacity to nitrogen and oxygen. When one tower adsorbs oxygen and produces nitrogen, the other desorbs oxygen and makes regeneration. This alternate process constantly produces nitrogen.
PN Series: Technical Specifications
Model | N2 Outlet Flow rate And Air Inlet Flow rate-Nm3/hr : 20ºC & 1013 mbar | Dimensions (L * W* H ) cm | Weight Kg | |||||||||||||||||
Type | Delicate Nitrogen Generator | Energy-saving Nitrogen Generator | ||||||||||||||||||
Oxygen content | 10 ppm | 50 ppm | 100 ppm | 500 ppm | 0.1% | 0.5% | 1% | 2% | 3% | 5 ppm | 10 ppm | 50 ppm | 100 ppm | 500 ppm | 0.1% | |||||
PN-200 | N2 | 5.3 | 7.5 | 8.7 | 11.6 | 13.3 | 19.6 | 24.3 | 30.4 | 34.6 | 2.7 | 3.3 | 5 | 5.8 | 7 | 8.1 | 130*60*170 | 700 | ||
Feed Air | 38 | 40.4 | 40 | 44.1 | 43.8 | 51.2 | 56.9 | 64.5 | 69.1 | 15.4 | 16.6 | 19.1 | 19.2 | 21 | 22.6 | |||||
PN-400 | N2 | 20.1 | 28.8 | 33.4 | 44.4 | 51 | 75.1 | 93 | 116 | 133 | 10.2 | 12.5 | 19.1 | 22.1 | 26.7 | 31.1 | 160*90*210 | 1500 | ||
Feed Air | 144 | 155 | 154 | 169 | 168 | 196 | 218 | 246 | 266 | 58.2 | 62.8 | 73.1 | 73.3 | 80.3 | 86.8 | |||||
PN-500 | N2 | 32.4 | 46.4 | 53.8 | 71.5 | 82.1 | 121 | 150 | 187 | 214 | 16.5 | 20.1 | 30.7 | 35.6 | 43 | 50.1 | 180*110*210 | 1900 | ||
Feed Air | 232 | 250 | 247 | 272 | 270 | 316 | 351 | 397 | 428 | 94.1 | 101 | 117 | 118 | 129 | 140 | |||||
PN-600 | N2 | 51.5 | 73.6 | 85.3 | 113 | 130 | 192 | 238 | 297 | 339 | 26.1 | 31.8 | 48.7 | 56.4 | 68.2 | 79.5 | 180*120*250 | 2550 | ||
Feed Air | 369 | 397 | 392 | 429 | 428 | 501 | 558 | 630 | 677 | 149 | 160 | 186 | 187 | 205 | 222 | |||||
PN-700 | N2 | 86.1 | 123 | 143 | 190 | 218 | 321 | 394 | 493 | 562 | 43.7 | 53.3 | 81.6 | 94.5 | 114 | 133 | 220*130*270 | 3200 | ||
Feed Air | 617 | 663 | 658 | 722 | 717 | 838 | 928 | 1051 | 1128 | 249 | 268 | 312 | 313 | 343 | 371 | |||||
PN-900 | N2 | 145 | 208 | 241 | 321 | 368 | 542 | 666 | 832 | 948 | 73.7 | 89.9 | 138 | 160 | 193 | 225 | 240*170*300 | 4200 | ||
Feed Air | 1040 | 1121 | 1109 | 1219 | 1211 | 1415 | 1569 | 1774 | 1903 | 420 | 451 | 528 | 531 | 580 | 628 | |||||
PN-1000 | N2 | 188 | 269 | 311 | 414 | 471 | 694 | 852 | 1065 | 1214 | 95.3 | 116 | 178 | 206 | 249 | 288 | 260*180*330 | 5100 | ||
Feed Air | 1348 | 1449 | 1431 | 1572 | 1560 | 1822 | 2018 | 2283 | 2449 | 543 | 582 | 681 | 683 | 749 | 809 | |||||
PN-1100 | N2 | 235 | 336 | 389 | 518 | 589 | 868 | 1065 | 1331 | 1517 | 119 | 145 | 222 | 258 | 311 | 360 | 300*190*350 | 6000 | ||
Feed Air | 1685 | 1810 | 1789 | 1967 | 1951 | 2279 | 2523 | 2853 | 3061 | 678 | 728 | 849 | 855 | 935 | 1011 | |||||
PN-1500 | N2 | 526 | 745 | 855 | 1138 | 1294 | 1907 | 2340 | 2924 | 3334 | 267 | 325 | 493 | 566 | 684 | 790 | 360*240*430 | 12000 | ||
Feed Air | 3772 | 4044 | 3991 | 4382 | 4343 | 5065 | 5603 | 6332 | 6792 | 1522 | 1632 | 1899 | 1901 | 2082 | 2246 | |||||
Reference Conditions: Compressed air effective inlet pressure: 7.0bar(g) Nitrogen outlet pressure: 6 bar(g) Ambient air temperature: 20 ºC Unit inlet air quality 1.4.1 according to ISO 8573-1:2010 Minimum refrigerant dryer required to precondition inlet air. Typical nitrogen quality 1.3.1 according to ISO 8573-1:2000. | Operating Limits: Minimum ambient temperature: 5ºC Maximum ambient temperature: 45ºC Maximum compressed inlet air pressure 10 bar(g) |
ServicesEngineering and Design HYT's engineers will design gas generating systems unique for your application and economic conditions.
Manufacturing HYT custom builds & assembles systems to accommodate your gas generating application.
Installation & Commissioning HYT's experienced and highly skilled technicians can assist you with system installation, start-up and commissioning. Our staff can also provide on-site operational training.
Maintenance & Repair HYT can provide regularly scheduled on-site maintenance checks to ensure your system functions at peak performance levels. HYT can also quickly dispatch our technical staff to repair your system, when necessary.
If you are interested in our product, please let us know your required:
1. N2 gas purity? %
2. N2 gas capacity? Nm3/h
3. The outlet pressure? Mpa/bar
4. Your local environmental condition (the annual humidity/the highest and lowest temperature/the altitude if it has)?
Then we can check accordingly.
Should you have any question, please feel free to contact us.
Manufacturing HYT custom builds & assembles systems to accommodate your gas generating application.
Installation & Commissioning HYT's experienced and highly skilled technicians can assist you with system installation, start-up and commissioning. Our staff can also provide on-site operational training.
Maintenance & Repair HYT can provide regularly scheduled on-site maintenance checks to ensure your system functions at peak performance levels. HYT can also quickly dispatch our technical staff to repair your system, when necessary.
If you are interested in our product, please let us know your required:
1. N2 gas purity? %
2. N2 gas capacity? Nm3/h
3. The outlet pressure? Mpa/bar
4. Your local environmental condition (the annual humidity/the highest and lowest temperature/the altitude if it has)?
Then we can check accordingly.
Should you have any question, please feel free to contact us.
Send your message to this supplier